Ventilator: It is a device that can replace, control or change the normal physiological respiration, increase the pulmonary ventilation volume, improve respiratory function, reduce the consumption of work of breathing, and save the cardiac reserve capacity of humans. Camshield can provide customers with two solutions relevant to ventilators: noninvasive ventilator: the ventilator is connected with patients through the mask, and invasive ventilator: the ventilator is connected to patients through endotracheal intubation.
Noninvasive ventilator | Invasive ventilator | |
Differences between ventilators | Low volume and simple panel | High volume and complex panel |
High flow, low pressure and good leakage compensation | Low flow, high pressure and poor leakage compensation | |
Simple setting of monitoring and alarming | Perfect setting of monitoring and alarming | |
Connection mode for ventilators | Connection through the oral-nasal mask, nasal mask or full-face mask | Connection through orotracheal, nasotracheal intubation or tracheotomy |
Mechanical ventilation mode | Less, BiPAP(Bi-level, I/E), CPAP, etc. | More, VCV, PCV, SIMV, PSV, etc. |
Suitable patients | Patients with mild-to-moderate respiratory failure | Patients with severe respiratory failure |
Scope of application | Intensive care unit (ICU), general ward, family | ICU |
Advantages | Preserve the normal physiological function of the patients (talking, expectoration, eating, etc.) | Good sealing performance of pipeline |
Less pain and easy tolerance | Good man-machine cooperation | |
Avoid the complications of invasive mechanical ventilation | Has air-oxygen mixture, and can accurately set the inhaled oxygen concentration | |
Avoid or reduce the use of sedatives | Easy guaranteed airway management | |
Relatively low medical expenses | Perfect setting of ventilation parameters and alarming, which can ensure accurate ventilation and timely find problems | |
Disadvantages | Poor airtightness of airway and easy leakage | Easy to cause facial injury |
Simple setting of monitoring and alarming | Complex pipeline connection and bulky | |
Mostly has no air-oxygen mixture, and can not accurately set the inhaled oxygen concentration | Can not preserve the normal physiological function of the patients | |
Not conducive to the drainage of airway secretions | Poor patients’ tolerance and need to use sedatives or muscle relaxants frequently | |
Insufficient gas heating and humidification | Common mechanical ventilation related complications (injury of the oral and nasal mucosa and the vocal cord, ventilator-associated pneumonia, ventilator-associated lung injury, etc.) | |
Easy to cause abdominal distension | Ventilator dependence is prone in some patients | |
High medical expenses |
Selected products(for more product models, please contact us):
Invasive & noninvasive combination ventilator | Specification: |
• Elegant and portable design
• 7″color touch screen with screen lock • Real-time display of 4 waveforms and 3 loops • Tidal Volume range:20-2500ml, I:E ratio1:59 to 99:1 • 17 ventilation modes: V-AC,V-SIMV, PRVC,PRVC+,P-AC P-SIMV,PCV,CPAP,CPAP+,BiPPV,BiPPV+,APRV,APRV+ CPR,RSA,HFNC • CPR mode according to AHA guideline • 2 trigger way: pressure and flow • 02 concentration adjustment from 40% to 100% (21% to 100% option) • Internal PEEP valve • Audible and visual alarm for multi-parameters • Optional Mainstream EtC02 with Respironics technology • Rechargeable Lion battery with 10 hours standby time, and 5 hours working time |
|
Certificate: CE,ISO |
ICU Ventilator | Specification: |
|
Ventilation mode
PRVC, APRV, DUOLEVEL, V-SIMV, P-SIMV, IPPV, P-A/C, V-A/C, PCV, PSV, PONT/CPAP, SIGH, MANUAL Ventilator parameter Tidal volume (Vt) :0~ 2000 mL Frequency (Freq): 1min~100min Oxygen concentration: 21%~100% l:E :4:1~1:8 PEEP: 0cmH2O~ 40 cmH2O Pressure triggering sensitivity (Ptr): -20 cmHzO ~ 20 cmHzO (Based on PEEP) Flow trigger sensitivity (Ftr) :0.5L./min ~ 30 L /min Pressure control (PC) :5 cmH2O ~ 80 cmH2O Pressure support (PS) :0 cmH2O ~ 80 cmH2O SIGH :0 (off) 1/100 ~ 5/100 Apnea ventilation :OFF,5s~60s Pressure limit :20 cmHzO ~ 100 cmH₂O Monitoring parameter Frequency (Freq): 0/ min~ 100 / min Tidal volume(Vt) :0mL~2500mL MV: 0L /min ~ 99 L ./min Airway pressure: 0 cmHzO ~ 100 cmH2O Dynamic lung compliance testing :1 mL/cmHzO ~ 1000 mL /cmHzO Oxygen concentration: 15%~100% Packing size Main components: L 560 * W 560 * H 605 mm G.W. :40KG, N.W.:17 KG Air compressor: L 670* W 700 * H 1160 mm G.W.:84 KG, N.W.: 46.2 KG |
Certificate: CE, ISO |
BPAP | Specification: |
General Info
Dimensions: 170 mm × 180 mm × 118 mm/290 mm × 180 mm × 134 mm (with the humidifier) Weight: 1.5 kg/2.5 kg (with the humidifier) Water capacity: 350 mL at recommended water level Ramp:The ramp time ranges from 0 to 60 minutes Humidifier:Humidifier Settings: off, 1 to 5 (95°F to 167°F / 35°C to 75°C) Humidifier Output: No less than 10 mg H2O/L SpO2 Range: 0 to 100% Pulse Rate Range: 40 to 240 BPM Sound Pressure Level:< 30 dB, when the device is working at the pressure of 10 hPa Storage:SD card can record patient data and fault information AC Power Consumption:100 – 240 V AC, 50/60 Hz, Max 2 A Key Parameters Target Vt: On/ Off 150~1500 mL Reslex: Patient, Off, 1~3 I Sens.: 1~8 E Sens.: 1~8 Res Rate: 3~40 BPM Ti: 0.3-3.0s Rise Time: 1~4 |
|
Certificate: CE, ISO |
Noninvasive ventilation (NIV): Suitable for patients with mild to moderate respiratory failure; offers noninvasive ventilation (NIV) to patients with respiratory insufficiency using a bilevel positive airway pressure (BiPAP) machine.
Invasive ventilation: Suitable for patients with severe respiratory failure or acute respiratory distress syndrome (ARDS) and those unable to sustain spontaneous breathing; facilitates the treatment of critically ill patients with an artificial airway.
Noninvasive/invasive ventilator: Intended to provide flexible ventilatory support for patients with moderate to severe acute/chronic respiratory insufficiency.
Address: Beijing, Haidian District, Xizhimen, Beida Street, Jia NO 43, Jinyun Building, Block B, Room 305-02
Contact number: +86-18518778855
Contact: Dr. Chenlong Gao
E-mail: [email protected]
Mobile:+86-18518778855